<?xml version="1.0" encoding="UTF-8"?>



<records>

  <record>
    <language>eng</language>
          <publisher>Oriental Scientific Publishing Company</publisher>
        <journalTitle>Biosciences Biotechnology Research Asia</journalTitle>
          <issn>0973-1245</issn>
            <publicationDate>2016-06-08</publicationDate>
    
        <volume>11</volume>
        <issue>Spl.Edn.1</issue>

 
    <startPage>81</startPage>
    <endPage>85</endPage>

	 
      <doi>10.13005/bbra/1394</doi>
        <publisherRecordId>11755</publisherRecordId>
    <documentType>article</documentType>
    <title language="eng">Studies on the Development of Biocatalyst for Emoval of Calcium from Water</title>

    <authors>
	 


      <author>
       <name>P. Bosco Dhanaseeli</name>

 
		
	<affiliationId>1</affiliationId>
      </author>
    

	 


      <author>
       <name>V. Balasubramanian</name>


		
	<affiliationId>1</affiliationId>

      </author>
    

	

	


	


	
    </authors>
    
	    <affiliationsList>
	    
		
		<affiliationName affiliationId="1">Centre for Ocean Research, Amet University, Kanathur, India.</affiliationName>
    

		
		
		
		
		
	  </affiliationsList>






    <abstract language="eng">One of the major problems that occur in a thermal power station is the formation
of scales inside the cooling towers. Cooling water system plays a vital role in thermal
power plants. Cooling water system removes the heat via evaporative coolers. Its primary
aim is to remove the heat absorbed in the circulating water system. Water is pumped from
the tower base into cooling water routed through the process cooler and condenser. The
cool water absorbs the heat from hot process system. The absorbed heat warms the
circulating water, which returns to the top of cooling tower and tickles downward towards
the materials inside the tower. The evaporated water leaves the dissolved salts in the
water which has not been evaporated thus salt concentration is increased in water. The
concentration of dissolved salts in the cooling water exceeds their solubility limits and
precipitates on the water surface and forms the scale. The microbes, which are ubiquitous
in nature, particularly the bacteria utilises some of the substrates as sole source for their
multiplication; sometime it may utilize a special component and can degrade the other
substances. Number of bacteria produces various bioproducts, enzymes; which are
responsible for the cleavage of complex compound into simpler ones. Thus the production
of enzyme urease by some bacteria plays an vital role in reducing calcium by utilizing the
anural substrate urea. The primary role of bacteria in the precipitation process has been
ascribed to their ability to create an alkaline environment through various physiological
activities. Immobilization of the microbes (biocatalysts) in specific matrices will further
improve the efficiency of the process.</abstract>

    <fullTextUrl format="html">https://www.biotech-asia.org/vol11_nospl_edn1/studies-on-the-development-of-biocatalyst-for-emoval-of-calcium-from-water/</fullTextUrl>



      <keywords language="eng">
        <keyword>Cooling tower; scales; calcium; antiscalants; microbes (bacteria); urease/urea; immobilization.</keyword>
      </keywords>

  </record>